ARU: ENTER ALARM NUMBER
YOU: ÝÝ
ARU: ALARM NUMBER 1.2 DTMF ON CODE IS EMPTY
YOU: 1 2 3 ÝÝ
ARU: ALARM NUMBER 1.2 DTMF ON CODE IS123
YOU: ÝÝ
ARU: DTMF OFF CODE IS EMPTY
YOU: 4 5 6 ÝÝ
ARU: DTMF OFF CODE IS456
YOU: ÝÝ
#X5ÝÝ : ALARM DEBOUNCE TIME
Alarm delay time (debounce time) can be set for each expander and must be between 0.1 and
9.9 seconds. One debounce time is used for all of the inputs on a particular expander. Each
expander may have a different time. The input must remain active for this period of time in
order for it to be considered a change of state.
Example: The debounce time for expander 2 is to be set at 3 seconds.
ARU: ENTER PROGRAM CODE
YOU: # 2 5 ÝÝ
ARU: NUMBER 2 ALARM DELAY IS 0.5 SECONDS
YOU: 3 0 ÝÝ
ARU: NUMBER 2 ALARM DELAY IS 3.0 SECONDS
YOU: ÝÝ
#X6ÝÝ : ALARM FORMAT
Each alarm input on an expander can be programmed to be Normally Open (N.O. - requiring
a ground closure to become active) or Normally Closed (N.C. - requiring a release from
ground to become active). The ALARM FORMAT must be a 0 for N.O. contacts ora1for
N.C. contacts.
Example: The inputs for expander two are to be set for normally closed inputs.
ARU: ENTER PROGRAM CODE
YOU: # 2 6 ÝÝ
ARU: NUMBER TWO ALARM FORMAT IS 0
YOU: 1 ÝÝ
ARU: NUMBER TWO ALARM FORMAT IS 1
YOU: ÝÝ
#X8ÝÝ : RELAY CONTROL TAGS
The four relays on each expander can have DTMF on and off codes programmed for remote
control. They will be announced as relay numbers X.1 to X.4 . The master will interpret
DTMF strings from the radio system as ON or OFF controls for the relays. Each string may
be up to 8 characters.
B1225E BARNETT ENGINEERING LTD. PAGE 8