1 OPERATION
1.1 GENERAL
The B1225E Alarm Expander Unit is an 8-input, 4-output board which expands the number
of alarm inputs and relay outputs. The expander boards connect to the B1225 ARU and to
each other via a serial cable. All of the programmable features of the B1225E are controlled
by the B1225 master, such as debounce time, relay on/off codes, DTMF on/off codes, input
polarity and voice messages.
The maximum number of expander boards which may be added to one B1225 ARU is seven.
Each expander has a binary address controlled by a DIPswitch on the board. The four relay
contacts available for remote control respond to DTMF codes received over the radio by the
master (B1225 ARU).
1.2 ALARM TRANSMISSION
When an alarm goes into an “active” state or a timer expires, the B1225 ARU goes through
the transmission sequence described in the B1225 operators manual: transmitting the master
site ID, master alarms, expander ID, and alarm conditions. The expander(s) will send out the
DTMF-on code and voice messages until the alarm returns to normal;then the DTMF-off
code is sent. A different DTMF code can be programmed for each input, providing eight
DTMF on and eight DTMF off sequences in total.
1.3 RELAY CONTROL
The four relay outputs are controlled through the master. By programming the “Relay on
code” and “Relay off code”, as shown in the programming section, the B1225E’s relays can
be remotely controlled.
When the master receives a Relay On (or Off) code over the radio system, it will turn the
corresponding expander relay on (or off) and transmit over the radio system the relay num
-
ber and new condition.
1.4 MEMORY STORAGE
The B1225E holds all of its operating parameters in battery backed up RAM. Internally, all
operating parameters are stored in two separate memory locations: a working space and a
redundant storage space. Both memory spaces are protected by a security code, ensuring
that all information is valid. Should one piece of data become corrupt in either of the data
spaces, it is automatically replaced with the valid data from the other location.
If a major error occurs and both the working and the storage data spaces have been cor
-
rupted, the B1225E will signal the master to reset all parameters concerning the expander to
default values. At this point the announcement “(SITE ID) - PROGRAM x CODE ERROR”
is made (x representing the number of the expander with the major errors).
Security codes and the RAM redundancy affect only the operating parameters and are not
used for the stored site identifier or alarm voices.