Overview
40 S1A53838 09/2011
External speed control potentiometer
1. Wire the analog input as indicated in the above figure.
2. Set switch SW100 to V (voltage).
3. Program common parameters of ATV212 (see Quick Menu page 55
).
4. Program specific parameters for external speed control potentiometer as indicated in the following table:
R/L1
S/L2
T/L3
U/T1
V/T2
W/T3
FLC
FLB
FLA
PP
PA/+PO
PC/-
SCR
A
GND
B
RUN
PRG
MON
%
Hz
MODE
Loc
Rem
ENT
RUN STOP
M
RYA
RYC
FM
F
R
RES
PLC
P24
CC
Sink
PLC
FM
Source
SW102
IU
SW101
Term
SW103
VIA U
VIB U
I
PTC
SW100
CC
VIA
VIB
2.2 to 10 kOhms
1/4 Watt
Parameter Page Setting Factory value
FMOd [Frequency mode sel] 77
1 [Ref source VIA] 1
F109 [VIA selection] 90
0 [AI] 0
F200 [Auto/man speed ref] 108
0 [Enable] 0