4 -
Black/Yellow Output :
Controls
the BLACK/YELLOW output activation type and
timing.
Pulse During
Crank
- Output becomes active with the same timing as the
starter output wire, during crank
only.
Ground
While
Running - Continuous output for the entire remote start
sequence
until after the vehicle
shuts down.
Ignition
- Output becomes active with the same timing as the ignition output
and does not drop out during crank.
Accessory - Output becomes active with the same timing as the accessory
output, drops out during crank.